Investigation on physico-mechanical properties and microstructural evolution patterns of heated gran
2025-02-25 19:51

Investigation on physico-mechanical properties and microstructural evolution patterns of heated gran

  

  Liquid nitrogen (LN2) fracturing is recognized as an innovative reservoir enhancement technique, demonstrating significant potential in establishing high permeability pathways in geothermal development. Understanding the physico-mechanical properties and microscopic mechanisms of hot dry rock post LN2 cooling treatment is pivotal for promoting the effective deployment of LN2 fracturing. This study undertook physical and mechanical testing on a quintessential hot dry rock type-granite-post various temperature and LN2 cooling treatments. Subsequently, a multi-scale investigation was conducted on the thermal fracture-pore structure's morphological features and the evolution of mineral components. The experimental findings indicated that LN2 cooling exerts a pronounced impact on the physico-mechanical properties of high-temperature granite. Temperature-induced damage to granite can be delineated into three phases: initial phase up to 200?°C where its effects are relatively imperceptible; an intermediate phase from 200 to 500?°C characterized by gradual deterioration; and a pronounced degradation phase evident at 600?°C. Correlations between the changes in the micro pore-fracture structure of granite and its physico-mechanical property degradation were subsequently established. As temperature escalated, the area of micro-defects in the CT-reconstructed spatial distribution increased progressively. The volumetric porosity damage ratio and fractal dimensions were quantitatively introduced to characterize the fractal geometric features and distribution patterns of internal thermal fractures in granite post thermal shock. Concurrently, NMR experiments indicated that with the escalation of temperature, micropore develop and interlink to form mesopore and macropore, enhancing rock porosity connectivity. These macropores significantly influence granite's physico-mechanical and permeability characteristics. A mineral stability analysis revealed that various minerals undergo physico-chemical reactions, such as dehydration, phase transitions, decomposition, and chemical bond fractures at elevated temperatures, altering mineralogical composition and mineral strength, thus impacting the rock's macroscopic properties. Ultimately, the study delved into the damage mechanisms of granite's physico-mechanical properties from both heating and cooling perspectives during various temperature phases. The insights garnered from this investigation offer novel value in comprehending the thermal damage characteristics induced by LN2 cooling.

  Geothermal energy stored in hot dry rock (HDR) represents a burgeoning renewable resource, boasting numerous advantages such as reduced carbon emissions, vast application prospects, and widespread distribution in comparison to conventional fuels like natural gas, petroleum, and coal (Pan et al. 2019, Anderson and Rezaie 2019, Xie et al. 2023). HDR is an intrinsically compacted geological formation situated at depths ranging from 3 to 10?km, exhibiting temperatures between 150 and 600?°C, and is predominantly devoid of water or steam content. This rock formation is primarily composed of granite (Breede et al. 2013). However, the intrinsic structure of HDR reservoir rocks is notably compact, exhibiting minimal permeability, which impedes the fluid flow and heat transfer within the reservoir (Asai et al. 2019). Hence, prior to geothermal extraction, it becomes imperative to enhance the reservoir's permeability either through physical or chemical stimulation. The prevalent method, hydraulic fracturing, is employed to enhance the permeability of the reservoir rocks (Kumari et al. 2018), a technique ubiquitously adopted across the oil, shale gas, and geothermal industries. However, hydraulic fracturing possesses certain undeniable disadvantages, such as significant water resource depletion, environmental contamination, and the inescapable issue of clay hydration expansion (Wang et al. 2016; Li et al. 2016). Additionally, traditional hydraulic fracturing often fails to generate intricate fracture networks. Addressing these challenges, liquid nitrogen (LN2) fracturing, as an advanced waterless fracturing technique, has been demonstrated to possess immense potential in establishing high-permeability pathway (Li et al. 2016; Wu et al. 2021). LN2 fracturing was first proposed by McDaniel et al. (1997) in 1990s for treating coalbed methane reservoirs, is now extensively applied in fracturing unconventional reservoirs. Owing to the extremely low temperature of LN2 (196?°C), when engaged in thermal exchange with the high-temperature reservoir, the resultant temperature differential induces intense thermal stress within the rock. Consequently, during the fracturing procedure, the reservoir undergoes significant thermal damage. This not only enhancement has improved the connectivity of the internal structure, significantly increasing the permeability of the reservoir rock, but also results in internal fracturing of the rock, precipitating a degradation of its physico-mechanical properties, thereby reducing its fracture pressure. Therefore, investigating the physico-mechanical attributes and flow characteristics of granite post-LN2 cooling, alongside elucidating the microscopic mechanisms of thermal damage, holds paramount importance for guiding engineering practices.

  Previous investigations extensively examines the physico-mechanical characteristics of high-temperature granite under both natural and water cooling processes. The density (Zhu et al. 2018), P-wave velocity (Hu et al. 2021), tensile strength (Jin et al. 2019), and uniaxial compressive strength (Jin et al. 2019; Hu et al. 2021) of cooled granite diminish as temperature rises, while porosity (Tang et al. 2019) and permeability (Jin et al. 2019) incrementally increase. The influence of temperature on granite is not a straightforward linear relationship. At specific temperature thresholds, there is a noticeable alteration in the rate of change of the granite's physico-mechanical properties. This can be attributed to certain physical or chemical reactions occurring within the rock at these temperatures, or a significant transformation in its internal structure. For instance, at a particular temperature, certain minerals within the rock may commence melting, crystallizing, or undergoing phase transitions, potentially resulting in rapid alterations in the rock's strength, elasticity modulus, and other properties. Similarly, upon reaching another temperature threshold, other minerals or structures may initiate reactions, leading to another shift in the property change rate. At the microscale, the observation primarily involves using XRD and SEM to assess the impact of thermal damage on mineral content and mineral structure. There is limited research dedicated to quantitatively analyzing the connection between the microscale and macroscale (Sun et al. 2017; He et al. 2023). Research on the physico-mechanical properties after LN2 cooling is relatively limited. Cai et al. (2014) investigated the effects of LN2 cooling on the pore structure of naturally occurring rocks. Their study revealed that LN2 cooling escalated the internal fracturing of the rock, enhancing crack quantity and opening. Wu et al. (2019a, b) assessed the physico-mechanical damage to rocks at different temperatures post LN2 cooling. Their findings indicated that after LN2 cooling, the permeability of heated granite notably increased, while its density, P-wave speed, strength, and elastic modulus decreased. A rise in temperature transitioned the granite from a brittle to a ductile state. Sha et al. (2020) discerned 400 °C as the threshold temperature for LN2-cooled granite. Beyond this temperature, the rock's physico-mechanical attributes experienced more conspicuous alterations. Microscopic analysis confirmed that the inception and growth of micro-cracks were responsible for the macroscopic property degradation of the rock. Wu et al. (2018) conducted experiments with LN2 jet rock-breaking. They observed that LN2 could form a mesh-like crack pattern on the rock's impact surface, reducing the threshold pressure for rock fracture during jet impact.

  From the aforementioned study, prior research on LN2-induced cryogenic damage predominantly focuses on the conventional physical properties and uniaxial compression tests of high-temperature granite. In practical engineering contexts, considerations regarding the impact of cooling media on reservoirs should not only focus on the deterioration of fundamental physical properties but also delve into the evolutionary characteristics of the rock's microscale pore-fracture architecture. This comprehensive understanding will offer a scientific foundation for future extraction activities. Conversely, there's a dearth of studies exploring the triaxial compression characteristics of granite under LN2 cooling, as well as the evolution of seepage properties under combined temperature and confining pressure conditions. Furthermore, the microscopic mechanisms underlying the damage to high-temperature granite post-LN2 treatment remain ambiguous. Consequently, a systematic analysis of the impact mechanism of LN2 cooling on granite is crucial for effective geothermal energy exploitation.

  In this study, the impact of thermal shock caused by LN2 cooling on the structural damage of granite subjected to different temperature treatments was examined through a series of physico-mechanical tests and microscopic observations. While the majority of currently exploited geothermal reservoirs maintain temperatures below 200 °C, advancements in technology and innovative methodologies may, in the future, target deeper and hotter reservoirs. Accordingly, granite samples were heated from room temperature to 600 °C in this study. The physico-mechanical properties of the granite samples, including density, porosity, P-wave velocity, and thermal conductivity, were meticulously measured. To ascertain the strength and deformational behavior of the granite sample, triaxial compression and Brazilian tensile strength test were conducted. Concurrently, the permeability of granite under varying confining pressures was evaluated, elucidating the percolation characteristics post deep-reservoir modification. Distinctly diverging from most existing study, which predominantly focuses on the macroscopic alterations in rock physico-mechanical properties, this study deployed CT scanning, mineralogical composition analysis, and NMR experiments to uncover the microscopic mechanisms dictating the physico-mechanical behavior of granite subjected to LN2 cooling. Conclusively, the evolution and mechanisms of granite damage were delved into from both heating and cooling perspectives. This research endeavours to pave the way for innovative strategies to augment the production of geothermal energy in HDR reservoirs.

  Granite is a typical rock type in HDR systems, and was selected as the experimental material for this study. The rock samples used in the experiment were sourced from Hubei Province, China, with an average density of 2.622?g/cm3. X-ray diffraction (XRD) analysis revealed that the primary mineral constituents of the samples are feldspar and quartz (shown in Table?1). Specimens were prepared in strict accordance with the specifications recommended by the International Society for Rock Mechanics (Ulusay and Hudson 2007), producing cylindrical samples of 50?mm in diameter and 100?mm in height, as well as disc samples of 50?mm in diameter and 25?mm in height. Prior to thermal treatment, the physico-mechanical properties of the rock samples were measured and tested. To minimize dispersion in the experimental results, specimens with P-wave velocity and porosity significantly deviating from the mean values were excluded, and the remaining specimens were numbered and grouped accordingly.

  Table?1 Mineralogical composition of granite specimens tested by XRD

  To ensure the precision of experimental results, granite specimens were categorized into seven distinct temperature groups, inclusive of ambient conditions. Each group consisted of one cylindrical specimen and one disc specimen. For each temperature group, the samples were subjected to three tests under identical conditions for their physico-mechanical properties, with the final results calculated as the average of these tests. Initially, the granite samples were heated in a KSL-1300X muffle furnace. Considering that too rapid a heating rate could induce thermal shock in the rock, leading to thermal cracking, this study opted for a slower heating rate. A rate of 5?°C/min was used to heat the granite samples to 150, 200, 300, 400, 500 and 600?°C, respectively. Upon reaching the target temperature, the samples were held at that temperature for 2?h to ensure adequate heating (shown in Fig.?1a). Subsequently, the samples were quickly removed and placed in an insulated container filled with LN2 for 1?h to ensure complete cooling. Notably, in actual engineering practice, when performing LN2 fracturing on geothermal reservoirs, HDR are subjected to two types of thermal shock loads: the freezing process and the thawing process. Since too rapid a temperature recovery rate during the transition from the frozen to thawed state could damage the rock (Hou et al. 2022), the focus of this study is on the impact of rapid cooling on the physico-mechanical properties of granite. Therefore, after thorough cooling, the frozen granite was placed in an insulated container to allow the temperature of the granite to gradually return to room temperature at a slow rate. Following this, the samples treated with LN2 were dried in a drying oven at 85?°C for 24?h before undergoing tests for their physico-mechanical properties, as depicted in Fig.?1b.

  Fig.?1figure 1

  a Thermal heating and LN2 cooling strategy; b Experimental procedure and apparatus

  Physical property tests were conducted on the heat-treated granite samples, including measurements of density, P-wave velocity, porosity, and thermal conductivity.

  Utilizing the principles of the triple-weight method, the density and porosity of specimens, both before and after thermal treatment, can be ascertained (Ulusay and Hudson 2007). Initially, granite specimens are submerged in water under a vacuum pressure of 0.1?MPa for 24?h to ensure saturation. They are subsequently transferred to an alternate water bath, where the mass of the saturated specimen in water, denoted as msat, is measured using an analytical balance. Following this, specimens are removed from the water, gently dabbed with a paper towel to eliminate excess surface water, and the saturated surface mass, represented as msub, is recorded. Ultimately, these specimens are dried in an oven at 85?°C for a span of 24?h, after which they are weighed to determine the dry mass ms. The granite specimen's density and porosity can be articulated as:

  (1)

  (2)

  where n signifies porosity, ρd represents dry density, msat is the post-saturation mass, mw is the saturated specimen's mass in water, ms indicates dry mass, and ρw denotes the density of water.

  Utilizing ultrasonic pulse transmission technology, the P-wave velocity of the samples before heating and after cooling was measured using a Panasonic FZ-G1 acoustic detector, with the sample positioned centrally between two sensors. Vaseline was applied to the interface between the sample and the transducers to ensure efficient energy transfer between them. Moreover, a constant pressure was applied to the sensors to achieve close contact with the sample. To ensure the reliability of the measurements, three sets of longitudinal wave velocity were recorded under each treatment condition, and their average value was calculated to represent the final P-wave velocity.

  In this experiment, the Transient Plane Source (TCS) method is selected to measure the thermal conductivity of granite, which offers advantages such as non-destructiveness, high accuracy, and precision, and does not require any special preparation of the samples prior to testing. The working principle involves heating a semi-infinite body through a moving point heat source and causing a change in the temperature field of the semi-infinite body as it moves relative to it. An infrared temperature sensor records the temperature change, which is related to the thermal conductivity of the granite.

  Mechanical tests were conducted on the GCTS Electro-Hydraulic Servo Rock Mechanics Testing System. This mechanical testing system comprises a loading system, a measurement system, and a control system, enabling precise measurements of the mechanical characteristics of samples under conventional triaxial compression.

  The compressive strength of the specimens was determined through triaxial compression tests. At the beginning of the test, a confining pressure of 20?MPa was applied at a rate of 1?MPa/min. Then, axial strain control was adopted at a rate of 0.001%/min until the sample failed, thus obtaining the rock parameters of the sample. Axial and lateral strains were measured using Linear Variable Differential Transformer (LVDT). The measuring range for both axial and lateral LVDT was 6?mm, with an accuracy of 0.0001?mm. Before testing, both LVDT were carefully calibrated.

  Furthermore, tensile strength tests on rocks were conducted using the Brazilian Splitting method, employing granite disk samples for this investigation. The disk specimens were subjected to a consistent loading rate of 0.005?mm/min until failure. The Brazilian Tensile Strength (BTS) can be defined as:

  (3)

  where σt represents the BTS, P is the load at failure, d denotes the diameter of the disk specimen, and t signifies the thickness of the disk specimen.

  Because granite is characterized by a dense texture, and the transient pulse permeability testing method is typically used for low-permeability compact rocks, the pulse decay method was employed for permeability measurements. In the test experiment, two gas chambers were connected to the upstream and downstream ends of the specimen, and confining pressures of 2, 4, 5, 10 and 15?MPa were applied sequentially, with the deviatoric stress maintained at 1?MPa. Helium gas was then introduced until the pressures in the upstream and downstream gas chambers equalized and reached equilibrium. While keeping the fluid pressure at the inlet constant, the fluid pressure at the outlet was instantaneously released, creating an initial pressure differential between the two ends. Continuous monitoring of the gas chamber pressures at both ends of the specimen yielded data used to calculate the permeability under the given stress condition:

  (4)

  (5)

  where K is the permeability; μ is the gas viscosity coefficient, Ls is the specimen height, Pm is the average pressure in the upstream and downstream chambers after completion, As is the cross-sectional area of the specimen, V1 and V2 are the volumes of the upstream and downstream gas chambers, respectively. S is the slope of the linear regression, △pD is the ratio of the final to initial pressure difference, and T is the test duration.

  The observation of microscopic fractures and pores in granite was conducted using CT technology with micrometric precision. The scan had a resolution of 15.6?μm, with the specimen being a cylinder measuring 50?mm in diameter and 100?mm in height. The scanning area spanned approximately 60?mm in height, with a scan interval of 20?μm per slice. Each test yielded approximately 3000 valid two-dimensional cross-sectional slices. Subsequently, the digital images were reconstructed using the image processing software Avizo. Additionally, to ascertain the evolution patterns of pore of different aperture sizes within the granite following high-temperature treatment, NMR was employed to examine the micro-pore distribution within the granite samples.

  Abstract

  Article Highlights

  1 Introduction

  2 Materials and methodology

  3 Experimental results

  4 Microstructural analysis

  5 Discussion

  6 Conclusion

  Availability of data and materials

  References

  Author information

  Ethics declarations

  #####

  3.1.1 Density

  The changes in the density of rocks under different temperature treatments can indicate the degree of structural loosening and deterioration in mechanical strength. Figure?2 depicts the density variations of granite samples before and after various temperature treatments. Following heating and LN2 cooling treatments, the density of all granite specimens decreased, and the rate of density change exhibited a negative exponential relationship. In this study, the change rate refers to the difference in a sample's property before and after thermal treatment relative to its value before the heat load. based on the magnitude of the decrease in density, the temperature range of 25–600?°C was divided into three phases. The first phase spanned from 25 to 200?°C; within this phase, the temperature exerted almost no effect on the granite's density, resulting in a minimal change rate. The second phase ranged from 200 to 500?°C, where the granite's density became increasingly influenced by rising temperatures, with a density reduction rate reaching 0.82% at 500?°C. During the third phase, ranging from 500 to 600?°C, the density of the granite declines rapidly, with the reduction rate reaching its peak. At 600?°C, the rate of decrease in density is 1.56%. This indicates that temperature has the most pronounced effect on the density within this phase.

  Fig.?2figure 2

  Density variation of granite samples versus temperature before and after thermal treatment

  3.1.2 Porosity

  Porosity is a fundamental physical attribute of rock, indicating the compactness of its internal structure and significantly influencing the rock's strength and deformation characteristics. Figure?3 depicts the variations in granite specimen porosity before and after distinct temperature treatments. Post-heating and LN2 cooling procedures, all granite samples displayed a reduction in porosity, with the rate of porosity alteration demonstrating a positive exponential relationship with temperature. based on the magnitude of the porosity increase, the temperature range of 25–600?°C is segmented into three phases. The first phase encompasses 25–200?°C, within which the temperature has a relatively gentle impact on the increase in granite's porosity, registering a 10.73% augmentation in porosity rate at 200?°C. The second phase, ranging from 200 to 500?°C, manifests an intensified influence on granite porosity alterations due to increasing temperature, culminating in an 81.07% increment in the porosity rate at 500?°C. The third phase, spanning 500–600?°C, showcases the most rapid surge in granite porosity rate, with the impact of temperature on the rate of change being the most pronounced; at 600?°C, the porosity growth rate reached 172.90% compared to untreated specimens.

  Fig.?3figure 3

  Porosity variation of granite samples versus temperature before and after thermal treatment

  3.1.3 P-wave velocity

  The P-wave velocity test has been extensively utilized to characterize thermal cracking in rocks and to assess internal rock damage. Given that the propagation speed of P-waves in solid media is significantly greater than in air, the evolution of micro-cracks due to thermal damage can be represented through the P-wave velocity. Figure?4 depicts the variation in P-wave velocity of granite samples before and after various thermal treatments. Upon heating and subsequent LN2 cooling, all granite specimens exhibited a decrease in their P-wave velocity, with the rate of this decline exhibiting a negative exponential relationship. based on the magnitude of the decrease in P-wave velocity, the temperature range of 25–600?°C is categorized into three phases. The initial phase, spanning 25–200?°C, witnessed a relatively inconspicuous decline in the granite's P-wave velocity, registering a decay of 12.75% at 200?°C. The second phase, from 200 to 500?°C, revealed that as the temperature increased, the impact on the P-wave velocity became more pronounced, culminating in a decay rate of 31.15% at 500?°C. In the third phase, spanning from 500 to 600?°C, the effect of temperature on the P-wave velocity of granite is most conspicuous. At 600?°C, the decrease in the P-wave velocity reaches 59.71%.

  Fig.?4figure 4

  P-wave variation of granite samples versus temperature before and after thermal treatment

  3.1.4 Thermal conductivity

  In geothermal energy extraction, the thermal conductivity characteristics of reservoir are crucial for the efficiency of geothermal extraction. Figure?5 illustrates the variation in thermal conductivity coefficients of granite samples before and after exposure to different temperatures. After being subjected to heating and LN2 cooling, the thermal conductivity coefficients of all granite samples decrease, and the rate of change in the thermal conductivity coefficient exhibits a negative exponential relationship. based on the extent of the decrease in thermal conductivity, the temperature range of 25–600?°C is divided into three phases. During the first phase (25–200?°C), the decay of the granite thermal conductivity coefficient is slow with respect to temperature. In the second phase (200–500?°C), the effect of temperature on the variation of granite's thermal conductivity coefficient increases, and by 500?°C, the rate of change in the thermal conductivity coefficient has decreased by 16.60%. In the third phase (500–600?°C), the rate of change of granite's thermal conductivity coefficient decreases the fastest, with the most significant impact of temperature on the rate of change, and at 600?°C, the thermal conductivity coefficient reduction rate reaches 31.25%.

  Fig.?5figure 5

  Thermal conductivity variation of granite samples versus temperature before and after thermal treatment

  3.2.1 Stress–strain curves

  The complete stress–strain curve of rock samples under triaxial compression tests can be divided into five stages. Under triaxial compression conditions, the axial stress-axial strain curve of rock can be categorized into: (1) crack closure stage, (2) elastic deformation stage, (3) stable crack propagation stage, (4) unstable crack propagation stage, and (5) post-peak deformation stage. The deviatoric stress versus axial, circumferential, and volumetric strain curves for granite samples subjected to different heating and cooling treatments are depicted in Figs. 6, 7 and 8, respectively. The axial stress-axial strain curve exhibits concavity in the initial loading stage. This nonlinear deformation of the rock is associated with the closure of thermally-induced microcracks within the rock during the loading process (Yang et al. 2017). As the temperature increases, the extent of concavity during the initial compaction phase gradually becomes more pronounced. Furthermore, as discerned from Figs. 7 and 8, granite subjected to higher thermal treatment temperatures exhibits more pronounced volumetric compression. These observations suggest that the elevation in thermal treatment temperatures leads to the formation of an increased number of thermal cracks within the granite. Following the crack closure phase is the elastic deformation phase, where axial stress increases linearly with axial strain. It's generally perceived that during this phase, no new micro-cracks are formed, and elastic modulus of the rock can be determined by the slope of this phase curve. With a further increment in axial load, the stress–strain curve gradient begins to diminish, indicating the onset and stable evolution of new micro-cracks within the specimen. The fourth phase is characterized by unstable crack development, where the growth of microcracks within the rock undergoes a qualitative change, resulting in the formation of pronounced macroscopic cracks, and the deformation behavior is dominated by dilatancy. Subsequently, the specimen reaches its peak strength and transitions into the post-peak deformation phase. Evident from Fig.?6, temperature considerably impacts the specimen's post-peak deformation. Within 200?°C, all granite samples exhibit a sudden stress drop after reaching peak stress, indicating their failure in a brittle manner. Beyond 200?°C, as the treatment temperature escalates, the peak strain incrementally rises, and the post-failure phase shifts from an abrupt drop to a stepped descent. Specimens transition from brittle failure to a more ductile form, with post-peak softening deformation becoming increasingly evident. This suggests a transformation from brittleness to ductility in granite as the temperature elevates.

  Fig.?6figure 6

  Stress-axial strain curve

  Fig.?7figure 7

  Stress-circumferential strain curve

  Fig.?8figure 8

  Stress-volumetric strain curve

  3.2.2 Strength characteristic

  Figure?9 shows the changes in triaxial compressive strength (σ1c) and BTS after thermal treatment at different temperatures. As the temperature rises from 25 to 200?°C, the decrease in peak strength is not significant, only dropping by 1.02%. With increasing temperature, the peak strength rapidly declines, and at 600?°C, the peak strength reaches its lowest point, representing just 9.84% of the intact sample. Meantime, as the target heating temperature increases, the BTS exhibits a decreasing trend. The BTS decreases very slowly between 25 and 200?°C. only when the heating temperature exceeds 200?°C does the BTS decrease significantly. At a target heating temperature of 600?°C, the BTS of granite under LN2 cooling decreases by 67.5%.

  Fig.?9figure 9

  Variation in σ1c and BTS of granite post LN2 cooling with temperature

  It can be observed that the deterioration of BTS in granite under the same temperature treatment is more pronounced than the decline in compressive strength, with BTS dropping by 67.5% at 600?°C treatment. This is because granite is a brittle material, with tensile stress being lower than any other types of stress. Moreover, studies conducted by Pai et al. (2021) indicate that transient thermal stresses caused by rapid cooling primarily affect the outer surface of the granite, with the maximum thermal stress being predominantly dominated by vertical thermal stress. This implies that the tensile properties of rocks are more sensitive to microstructural damage than compressive properties.

  3.2.3 Deformation characteristic

  The elastic modulus of rock is a key mechanical parameter in the compressive deformation process, directly affecting the rock's ability to resist deformation and reflecting the micro-characteristics of the rock's mineral composition and crystalline structure. Figure?10 reveals a significant impact of temperature on the elastic modulus, with the modulus decreasing gradually as the temperature increases. At temperatures below 200?°C, there is a slight decrease in the elastic modulus, with a reduction of 0.99% compared to untreated samples. However, as the temperature exceeds 200?°C, thermal treatment leads to further deterioration of the elastic modulus, which reaches its lowest value at 600?°C, registering a decline of 23.32% compared to untreated samples.

  Fig.?10figure 10

  Variation of elastic modulus and Poisson's ratio of granite post LN2 cooling with temperature

  The Poisson's ratio is defined as the ratio of lateral to axial strain. Figure?10 illustrates the variation of Poisson's ratio with heating temperature. For granite subjected to heating and LN2 cooling treatments, the Poisson's ratio initially increases with the rise in heating temperature and then swiftly decreases at 600 °C. The initial increase in Poisson's ratio is attributed to the transition of granite from brittle to ductile behavior due to the temperature elevation, causing the rock to soften. This can be described by the equation:

  (6)

  where K is the bulk modulus, E represents the elastic modulus, and v denotes the Poisson's ratio. based on the equation, it can be inferred that a larger v implies a smaller K, indicating a softer (ductile) material. However, upon reaching 600?°C, due to a phase transition in quartz, one of the primary mineral constituents within the granite, its crystal structure shifts from tetragonal to hexagonal crystalline structures. This alteration in atomic arrangement (Chaki et al. 2008) results in reduced inter-atomic spacings, subsequently leading to a rapid decline in the Poisson's ratio (Wang 2013).

  Failure strain is defined as the axial strain corresponding to the peak strength, offering insights into rock deformation characteristics to a certain extent. Figure?6 delineates the variation in failure strain with respect to thermal treatment temperature. The findings reveal conspicuous changes in failure strain due to distinct heating temperatures. Generally, the failure strain of granite specimens augments with temperature escalation, witnessing a precipitous rise in the range of 500–600?°C for all samples. Furthermore, the slope of the stress–strain curve diminishes with rising temperature. This can be ascribed to the enhanced pores and thermal fractures formation within granite as temperature increases. Consequently, at the same stress level, the samples exposed to higher temperatures require greater axial displacement during the compaction stage to close these pores and micro-cracks. Therefore, the continuously increasing failure strain is primarily attributed to the larger displacements needed during the crack compaction phase, and it also reflects that the increase in temperature endows granite with greater ductility.

  Thermal stress induced by high temperatures significantly alters the microstructure within the rock, leading to the formation of new thermal cracks and pores, which in turn results in changes in the permeability characteristics of the rock.

  Figure?11 illustrates the permeability of samples at varying temperatures. As the initial temperature elevates, the permeability of rock specimens subjected to LN2 treatment notably increases. During the initial phase ranging from 25 to 200?°C, there's a gradual rise in permeability. Under a confining pressure of 2?MPa at 200?°C, the permeability of the sample increased by 2.14 time compared to the untreated specimen. As the confining pressure increases, the growth rate of permeability slows down at each stage, with the permeability of the 200?°C sample only increasing by 0.18 time compared to the untreated sample under a confining pressure of 20?MPa. The main reasons for these observations are as follows:

  (1)

  Within 200?°C, due to the small temperature gradient, the closure of pores and thermal cracks during heating weakens the expansion of some cracks caused by thermal shock during cooling, so the overall increase in the number and openness of seepage pathways is not significant, leading to slow growth of permeability during this stage.

  (2)

  As the temperature rises, free water and bound water escape, opening flow channels, but confining pressure and thermal expansion close these channels (Ding et al. 2022).

  (3)

  The increase in temperature causes softening of some of the solid framework, affecting the connectivity of flow channels (Feng et al. 2018).

  Fig.?11figure 11

  Three distinct phases of permeability trend following treatment at 25–600?°C

  As the temperature continues to rise from 200 to 500?°C, the permeability increases rapidly. At a confining pressure of 2?MPa, the permeability of the sample treated at 500?°C is 1.62?×?10?15?m2, which is two orders of magnitude greater than untreated specimen. This is due to the fact that thermal stress exceeds the bonding force between mineral particles, resulting in thermal fracturing, and volume and surface area of the total pore-fracture structure increase rapidly with temperature. Consequently, the number and connectivity of flow channels within the sample are enhanced. When the temperature reaches the third stage at 600?°C, the permeability growth rate reaches its maximum. At 2?MPa, the permeability is 6.60?×?10?15?m2, which is 244 times greater than that at room temperature. This can be attributed to the phase transition of quartz from α to β, causing a significant expansion of the mineral volume, leading to intergranular and intragranular cracks. Numerous interconnected cracks and secondary cracks appear inside the rock. Additionally, thermal shock causes a large number of minerals to detach from the surface, resulting in an increase in internal voids.

  When confining pressure is applied to the sample, cracks and pores deform and close, leading to the suppression of fluid flow channels and a subsequent reduction in permeability. Granite flow channels consist of three types: fractures, pore throats, and pores. Pores, with their arch-like bearing surfaces, undergo little volume change under compressive stress. Pore throats, subjected to tensile stress and with smaller radii, are more prone to closure when compressed. According to the CT scan results in Sect.?4.1, these two components did not exhibit significant development or expansion under thermal stimulation. Compared to pores and pore throats, fractures, which lack support from the skeletal matrix, are more susceptible to deformation and closure (Chen et al. 2017). The connectivity of fluid flow channels is primarily influenced by the extension and closure of fractures, while pore throats and voids have a lesser impact on permeability compared to fractures. As illustrated in Fig.?12, at various temperature stages, as the confining pressure increases, the decline in permeability at higher confining pressures is less than the decline at lower confining pressures.

  Fig.?12figure 12

  Contour map of permeability changes under temperature and confining pressure effects post treatment at 25–600?°C

  ccDownload:/content/pdf/10.1007/s40948-023-00720-2.pdf